3phase Dc Inverter Heat Pump HVAC System Low Energy Heat Pump 50Hz
Negotiable
MOQ
Negotiable
Price
3phase Dc Inverter Heat Pump HVAC System Low Energy Heat Pump 50Hz
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: LN
Certification: CE ISO CCC
Model Number: KCHR-15II/BP (Out of the wind)
High Light:

3phase Low Energy Heat Pump

,

R407C Low Energy Heat Pump

,

380V Low Energy Heat Pump

Payment & Shipping Terms
Packaging Details: standard export package, or as per customer request
Delivery Time: 1-30 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 80000pcs/year
Specifications
Voltage: 380V 3N~50Hz
Refrigerant: R410a,R134a,R22/R407C
Working Ambient Temperature: -25C To 43C
Voltage: 380V/3phase/50HZ,220V-50Hz
Type: Monoblock Air Source Heat Pump,Air To Water Heat Pump
Usage: Domestic Hot Water, Commercial Hot Water Solution, Heating And Cooling
Product Description

Strength of Air To Water Heat Pumps Innovative Low-Energy HVAC Systems

Adopt famous brand Copeland compressor

2 rust prevention and corrosion prevention

Titanium alloy/navy copper special heat exchanger assembly, acid and corrosion resistance.

3. Economic energy saving

It is 75% cheaper than electric water heater, 55% cheaper than gas water heater and 15% cheaper than solar electric auxiliary

4. Strong stability

Not easy to damage, stable, durable, stable operation.

5. Anti-scaling design

The material of heat exchanger is improved, and the retention of dirt molecules is reduced and the heat transfer efficiency is improved by optimizing the pipeline design.

6. Humanized design

The interface is friendly, the man-machine operation interface is simple and clear, easy to use.

Applicable: apartment, hotel, rental room, factory school dormitory, hair salon, guesthouse, hotel, large club, health club, sauna bath center

Product introduction: Circulating air energy heat pump water unit adopts Panasonic or gluten compressor, four-way valve, expansion valve, the performance of the unit is more superior, more stable; Microcomputer LCD controller, no need for special care; Intelligent frost technology, no pollution to the environment; Evaporator using hydrophilic diaphragm, strong heat absorption, high efficiency, corrosion resistance; Easy installation, small footprint, save investment.

Even at extreme outdoor temperatures.

Environmentally friendly.

Wide range of solutions: floor heating, radiators and fan coils.

Energy class A++

Free domestic hot water in summer

Minimal architectural impact

Increase in building value

Fast and effective cooling

Operating range from -32°C to +50°C

Elevated seasonal efficiency

DHW temperature up to +75°C

 

Leomon heat pumps introduction for Air To Water Heat Pumps Innovative Low-Energy HVAC Systems

Leader for air source heat pumps, decades experience,authorized over100 patents, leader for swimming pool air source heat pumps and other pumps, member for editing heat pumps field standards, strong and professional technical team

Our strong and professional technical and marketing team ready to make best service!

Pre order(Inquiry progress):

Check with customer about usage, request specifications, enviroment and other request

Make details proposal/offer to customer

Order Processing

  • Machine installed and tested by QA engineers.

  • Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.

  • Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.

  • Test and debug the equipments strictly to ensure the safety and stability.

  • During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers

  • After sale service

  • 2 years warranty

  • Feedback and solution will be provided within 1 working day

  • Free technical support!

  • Technical paremeters for Monoblock Split DC INVERTER SYSTEMS Smart Energy Solutions

  • Normal temperature Air source heat pumps
    Spec. KFXRS-9I/CY KFXRS-11I/CY KFXRS-11II/CY KFXRS-19I/CY KFXRS-19II/CY KFXRS-28II/CY KFXRS-42II/CY
    Nominal heating capacity at room temperature(kW) 9.6 10.8 10.8 19 19 28 42.5
    Nominal input power at room temperature(kW) 2.17 2.7 2.7 4.19 4.19 6.2 9.2
    Rated voltage(Hz) 220V-50 220V-50 380V3N-50 220V-50 380V3N-50 380V3N-50 380V 3N-50
    Low temperature heating(kW) 7.8 8.8 8.8 15.5 15.5 23 34.5
    Low temperature input power(kW) 2.15 2.65 2.65 4.18 4.18 6.18 9.1
    Maximum input power(kW) 3 4.2 4.2 8 8 8 16
    Maximum current(A) 16 23 8 32 13 13 24.5
    noisedb(A) <55 <63 <63 <66 <66 <62 <63
    Anti-shock level I
    waterproof level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
    Caliber of outlet DN20 DN20 DN20 DN32 DN32 DN32 DN40
    Unit size (mm) 1010x350x835 1030x410x865 1030x410x865 1030x410x1390 1030x410x1390 820x780x1700 1550x780x1700
    Unit Weight(kg) 84 88 88 126 126 260 400
  •  
  • 3phase Dc Inverter Heat Pump HVAC System Low Energy Heat Pump 50Hz 0
  • 3phase Dc Inverter Heat Pump HVAC System Low Energy Heat Pump 50Hz 1
  •  
Recommended Products
Get in touch with us
Tel : 15215554137
Fax : 86-555-2842689
Characters Remaining(20/3000)