DC Inverter Compressor Commercial Air Source Heat Pump 220V
Negotiable
MOQ
Negotiable
Price
DC Inverter Compressor Commercial Air Source Heat Pump 220V
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: LN
Certification: CE ISO CCC
Model Number: DKFXRS-9I/CY
High Light:

2.81 COP Heat Pump

,

50Hz Commercial Air Source Heat Pump

,

220V Commercial Air Source Heat Pump

Payment & Shipping Terms
Packaging Details: standard export package, or as per customer request
Delivery Time: 1-30 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 80000pcs/year
Specifications
Heat Source Type: Air Source Heat Pump
Compressor: Panasonic DC Inverter Compressor
Motor: DC Inverter Brushless Motor
Function: Heating, Cooling, Hot Water
Power Supply: 220V-415V
TelAmbient Air Temp: -30 To 43 Degree Celsius
Product Description
THE MOST ENERGY EFFICIENT AND INNOVATIVE SOLUTION OF GETTING DOMESTIC HEATING & COOLING & HOT WATER BY USING AIR SOURCE HEAT PUMP
Features of Ideal Heating Solution Air Source Heat Pump
Air source heat pumps (ASHPs) are an ideal solution for most project types and sizes, as they don’t require as much space and are generally easier to install than a ground or water source heat pump.

Ease of installation

ASHPs offer quick and easy installation as they only require an electrical and water supply connection. Their key consideration is to allow for air flow, making them an ideal solution for projects where space for a ground or water collector is limited.

Efficiency and range

Heat pump efficiency is measured as a Coefficient of Performance (COP). Our highly efficient ASHPs have a COP of circa 3.5+ at a water temperature of 35°C, including internal and external units, with reversible options for comfort cooling. We also offer evaporator protective coatings to extend system life-span against corrosion.

Testing and standards

GDHV have multiple heat pump factories, including in Germany, France and Ireland, with access to state-of-the-art testing facilities to provide you accurate heat pump information. Our products are tested to the latest EN standards, including EN15316, EN14511 and EN14825.

Application design

When choosing our ASHPs our application engineers will be able to offer advice on applying the solution to your project. This includes hydraulic schematic advice for single and cascaded units, alongside guidance on buffer vessels and water cylinders.

 

CORE TECHNOLOGIES of Renewable air to water heat pumps for houosehold
DC INVERTER COMPRESSOR Twin-Cylinder Rotary DC Inverter Compressor
INVERTER TECHNOLOGY: 40Hz-120Hz Wide Frequency operation range
SMART CONTROL SYSTEM:Hitachi DC Inverter Control System

The kinetic energy of subdivision, the water tank is free of washing for lifespan

Closed refrigerant system, safe and stable

Gold - aluminum condensation process rapid frost

Ship cabin positioning monitoring system, accurate detection of water temperature

Heat pumps provide improved air quality to business premises, operate with low noise and can be used as air conditioning.
Research estimates that commercial heating alone is responsible for around 40% of CO2 emissions. With this in mind, forward-thinking businesses looking to enhance their green credentials are finding innovative ways to sustainably heat business premises.
Heat pumps are 300% to 400% more efficient than electric heating, delivering approximately 4kWh of energy for every 1kWh of electricity used to power it.
If you are considering an air source heat pump for your business, get in touch with our team. We can help with any questions you have and provide advice and recommendations to maximise the benefits you’ll receive.

We are serious about providing high-quality, tried and trusted sustainable energy technology for businesses like yours. As a top manufacture of various air source heat pumps,  we provide hassle free heating to commercial premises. The range we recommend are among the greenest and most efficient solutions currently available on the market.

 

Air source heat pumps series and application: Water heaters heat pump, swimming pool heat pumps, spa heaters, Radient/underfloor heating,cooling and hot water muldtifunction all in one heat pump

Application: swimming pool, household hot water, schools, restarants, Sauna, spas, day care center`````

 

We have various specifications and types of Ideal Heating Solution Air Source Heat Pump to offer, welcome to contact for furthder details

Triple supply parameters Cooling, heating and hot water functions
Item KCHR-8I/BP
Side wind
KCHR-13I/BP
Side wind)
KCHR-15I/BP
Side wind
KCHR-15II/BP
(Out of the wind)
Rated voltage 220V~50Hz 220V~50Hz 220V~50Hz 380V 3N~50Hz
Cooling and heating Nominal cooling
capacity
7.8kW(2kW-9kW) 13kW(3kW-15kW) 14.5kW(4kW-16.5kW) 14.5kW(4kW-16.5kW)
Nominal cooling power
consumption
2.77KW 4.6KW 5.27KW 5.27KW
Nominal cooling(COP) 2.81 2.82 2.75 2.75
IPLV 4.11 4.13 4.02 4.02
Nominal heating capacity 8.4kW(2.5kW-9.6kW) 14kW(3.5kW-16kW) 17kW(4.3kW-18.5kW) 17kW(2.5kW-18.5kW)
Nominal heating power
consumption
2.78KW 4.5KW 5.6KW 5.6KW
Heating Nominal heating capacity 6.8KW 10.5KW 13KW 13KW
Nominal heating
power consumption
1.75KW 2.65KW 3.3KW 3.3KW
Nominal heating(COP) 3.88 3.96 3.93 3.93
Maximum operating current 20A 33A 41A 21A
Maximum power consumption 4KW 6.6KW 7.9KW 7.9KW
Rated water flow 1.34m²/h 2.24m²/h 2.5m²/h 2.5m²/h
Refrigerant/charge volume R410A/1750g R410A/4000g R410A/4000g R410A/4800g
noise ≤54dB(A) ≤56dB(A) ≤57dB(A) ≤58dB(A)
Water resistance ≤14kPa ≤15kPa ≤21kPa ≤21kPa
Maximum working pressure on low
pressure/high pressure side
4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa
Allowable working pressure on
suction/exhaust side
4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa
Anti-shock level I I I I
waterproof level IPX4 IPX4 IPX4 IPX4
Unit size (l× w × h) 1030×410×865(mm) 1030×410×1390(mm) 1030×410×1390(mm) 820×780×1700(mm)
(Cold and warm) Caliber of inlet
and outlet
DN25 DN32 DN32 DN32
(Hot water) Caliber DN20 DN25 DN25 DN25
Application area 60㎡ 100㎡ 110㎡ 110㎡
Some projects of Ideal Heating Solution Air Source Heat Pump
 
 
DC Inverter Compressor Commercial Air Source Heat Pump 220V 0
DC Inverter Compressor Commercial Air Source Heat Pump 220V 1
 
 
 
 
 
Recommended Products
Get in touch with us
Tel : 15215554137
Fax : 86-555-2842689
Characters Remaining(20/3000)