Air source heat pump water heater is a device that moves heat from the air around to heat water, then satisfy the user's daily demand for hot water. Its working principle is based on the Reverse Carnot Cycle principle. Usually, a heat pump water heater has four main components: evaporator, compressor, condenser and expansion device. The refrigerant is the medium to connect the four parts. Just using a little mount of electric power, the liquid refrigerant in the compressor will be pumped into high temperature and high pressure gas. After flow through the heat exchanger, the heat will be released to heat water to satisfy the user's demand. After that, the refrigerant become middle temperature and middle pressure liquid. The refrigerant continues moving to the expansion device and becomes low temperature and low pressure liquid. When flowing through the evaporator, the refrigerant will be evaporated to gas and back to the compressor. The cycle starts again.
With Leomon heat pump technology, the unit is capable of producing 4 times energy by absorbing the heat from the air, with hi-output, the energy efficiency and environmental value of the unit can radically surpass that of a single effect system which can only produce either hot water or cool air and traditional system that is driven by primary energy resources, which lessens the impact on the environment.
DHW Electric air source inverter heat pump For Swimming Pool Dehumidified 220KW
High COP
By incorporating green R410A refrigerant and technology from SCL(USA), heat exchanger with innovative technology and and circulating heating method, Leomon heat pump is able to maintain its COP as high as around 4.6 during operation and has acquired the first class energy label, which means it can benefit to cut more than 15% running expenses annually for the users.
Water Temp. up to 55oCWith Apricus special high temperature heat pump technology, Apricus heat pumps feature a wide operating temp. range. They can reach high tem. (55oC) even in cold climate ranging from -7oC to 43oC, and can work safely and reliably at ambient temp. as low as -7oC and still enjoy efficient energy saving experience.
Cleaning-free Water TankThe unit can adjust to various installation location, such as inside a basement, on the ground floor and even on the roof, which makes it so flexible for fast, low cost installation.
Our Projects
20-25kw air source heat pump for swimming pool heating and cooling
Modular intelligent energy saving control
Adopt air energy water circulation, American SCL heat exchange technology, direct water circulation, but the heat exchange plate, efficient operation; Bolang pool heat pump compressor can be put into use in stages according to the change of water temperature, and the energy saving effect is more outstanding.
Stable performance
Fully enclosed refrigerant design, no refrigerant for life, maintain lasting constant temperature effect, low failure rate.
Good anti-fouling effect
The use of titanium tube heat exchanger, not only has high efficiency heat transfer capacity, but also can effectively avoid the corrosion of heat exchanger caused by acidic substances in the pool, reduce scale precipitation.
Perennial constant temperature control
Adopts constant temperature control system. The water inlet temperature of the pool heat pump is 25 ° C and the water outlet temperature is 30° C, which can keep the water temperature of the pool 26-28 ° C.
Beautiful and longer lifespan
Full stainless steel shell, service life up to 15 years.
Closed refrigerant system, safe and stable
Fluorine refrigerant system leakage points, easy to lead to frequent leakage of refrigerant, reduce equipment performance and service life. water machine system adhere to the international standard of closed refrigerant design, the unit in high or low temperature conditions also has excellent heat transfer efficiency.
The kinetic energy of subdivision, the water tank is free of washing for life
air domestic water tank can be heated in three chambers, dynamic water circulation, to prevent muddy water, scale, the water tank life free washing, to ensure that the household hot water clean, healthy; At the same time, the subdivision heating technology can ensure that the hot water output reaches 100%, and the hot water output of 150L is equivalent to that of 200L of similar products.
Three point temperature control, real-time detection of water temperature
air domestic water tank adopts three-point temperature control technology, which can detect the water temperature in real time to ensure that hot water is available immediately.
Integrated process of floor heating and air conditioning reduces installation faults
In the strategic deployment of "integration of host parts" for Bolang floor heating air conditioners and ultra-low temperature heating machines, Hydraulic balancer and floor heating air conditioners integrator have been released to reduce the installation threshold and installation faults, save installation time, and improve the quality of the whole machine and the energy efficiency of the system.
Ship cabin positioning monitoring system, accurate detection of water temperature
Air commercial hot water unit adopts ultrasonic rangefinder to measure the distance between the water surface and the reference position. The weak current power supply is adopted. The ultrasonic rangefinder does not directly contact with the water in the hot water storage box, which makes it safer to use
Dual working conditions of broadband diversion technology, prolong the life of the unit
Leomon commercial heat pump unit dual working conditions of broadband diversion combined with temperature compensation technology, in the state of temperature change, to ensure the compressor to achieve the best working state, prolong the service life, improve thermal efficiency.
Modular control system reduces energy loss
The host provides moderate energy requirements according to the end, reducing unnecessary energy loss.
The main machine does not contain electricity auxiliary heat, energy saving
The host machine of all series products of Leomon does not contain electricity and auxiliary heat, which saves unnecessary operation cost.
FAQ:
Q: What is your strength in heat pump industry?
A: Decades experience in the field of heat pumps for more than 19 years. Over 300 patents, leader member for ediiting heat pumps standard.
Q: Do you accept OEM & ODM?
A: Yes. We can supply products under clients' brand, modify the products to satisfy client's personalized requirements and work together with clients to design and produce a totally new products.
Q: What support do you offer to clients?
A: We can: provide product certification requirements for local markets; provide catalogs, technical manuals; co-exhibit with the clients in leading industry exhibitions; do promotion on the local market’s media by our news release resources.
Q: Could I have a sample to check the quality ?
A:Yes, sample order is okay.If the model in stock, we even can ship immediately.
Q:Why is air to water heat pump a recommended heating solution?
A:Using renewable energy reduces your environmental impact while allowing you to save money. A correctly installed air to water heat pump system that is specific to your home's dimension lowers your heating costs by up to 50%.
Specification of 20-25kw air source heat pump for swimming pool heating and cooling
Constant temperature swimming pool heat pump | |||||||
Spec. | KRY-8II | KRY-12II | KRY-24II | KRY-48II | KRY-96II | KRY-145II | KRY-220II |
Rated heating capacity(A24/26oC) | 8kw | 12kw | 24kw | 48kw | 96kw | 145kw | 220kw |
Rated power(kW) | 1.56 | 2.35 | 4.7 | 9.3 | 18.5 | 23.6 | 42.5 |
COP | 5.1 | 5.1 | 5.1 | 5.16 | 5.41 | 6.14 | 5.17 |
Rated heating capacityA20/26oC | 7.5kw | 11kw | 21kw | 44 kw | 90kw | 138kw | 208kw |
Rated power(kW) | 1..5 | 2.3 | 4.5 | 8.6 | 17.5 | 24.1 | 41.5 |
COP | 5 | 4.78 | 4.66 | 5.11 | 5.14 | 5.73 | 5 |
Cooling Capacity(kW) | 3.8 | 5.7 | 11.3 | 23.7 | 40 | 58.1 | 98 |
Consumed Power(kW) | 1.67 | 2.5 | 4.9 | 9.1 | 18.2 | 24.2 | 39 |
EER | 2.3 | 2.3 | 2.3 | 2.6 | 2.2 | 2.4 | 2.5 |
Rated voltage(Hz) | 220V 50HZ | 220V 50HZ | 380V 3N-50HZ | 380V 3N-50HZ | 380V 3N-50HZ | 380V 3N-50HZ | 380V 3N-50HZ |
Maximum input power(kW) | 2 | 3 | 6 | 12 | 24 | 36.5 | 61 |
Maximum current(A) | 8 | 12 | 24 | 42 | 80 | 90 | 130 |
Water flownWh | 2.3 | 3.5 | 7 | 13 | 32 | 41 | 62 |
noise dB(A) | <50 | <50 | <65 | <68 | <69 | <71 | <73 |
Anti-shock level | I | I | I | I | I | I | I |
waterproof level | IPV4 | IPV4 | IPV4 | IPV4 | IPV4 | IPV4 | IPV4 |
Unit size (mm) | 910x350x835 | 1030x410x865 | 780x820x1700 | 1550x780x1700 | 1550x1550x1700 | 2360x1550x1840 | 2206x2020x2170 |
Unit Weight(kg) | 65 | 95 | 260 | 380 | 760 | 2100 | 4005 |
Welome to contact us For the most suitable Heating,Cooling,Hot Water Solution!