logo
Send Message

4 Prerequisites for Efficient Heating of Air Source Heat Pump

March 10, 2012

Latest company news about 4 Prerequisites for Efficient Heating of Air Source Heat Pump

Air source heat pump is a process in which the heat pump heats the water, and then transmits the hot water to the end such as floor heating, fan coil heating, copper and aluminum radiator heating through the pipeline circulation water pump to transfer heat to the house. From this, we can see that the heating temperature has a lot to do with the air source heat pump, heating pipeline, and heating end.

 

When it is found that the air source heat pump is difficult to heat up, we should check whether the heat pump is reasonably selected, whether the heat pump has any faults, and then check whether the insulation effect of the heating system is not good, or the heating end is too small, etc.

latest company news about 4 Prerequisites for Efficient Heating of Air Source Heat Pump  0

1. Air source heat pump host

1) Choose a dedicated ultra-low temperature air source heat pump

Depending on the heating area, whether to choose a dedicated heat pump or not, in the heating area, a professional ultra-low temperature air source heat pump should be selected to ensure that the air source heat pump operates efficiently in a low temperature environment. For example, Leomon low temperature air source heat pump uses a jet enthalpy increase compressor, unique intelligent frost technology, and inverter technology to ensure that the low temperature air source heat pump operates efficiently in an environment of -25 degrees to meet heating needs.

 

2) Reasonable selection of radiator

When selecting heat pumps and terminals, choose the corresponding air source heat pumps and heating terminals according to reasonable load selection.

 

2. Professional installation of air source heat pump heating system

1) For host installation, choose the installation location of the air source heat pump according to the manufacturer's recommendations, ensure that the heat pump is ventilated, away from residential areas, or places with noise requirements, and away from places where objects fall.

 

2) Try to take insulation measures for the heating system and terminals, and choose reasonable heating terminals.

 

3. Take appropriate insulation measures in the heating area, such as closing doors and windows, or putting up curtains in places with many windows.

 

4. Resolve the faults of the air source heat pump system. During use, check whether there are heat pump faults, heating system short circuit faults, heating terminal faults, etc.

Get in touch with us
Contact Person : Ms. Kelly
Tel : 15215554137
Fax : 86-555-2842689
Characters Remaining(20/3000)