Air source heat pumps may encounter various malfunctions during daily use, which can be mainly summarized into the following categories:
1. Poor heating/cooling performance or low efficiency
This is one of the most common complaints. When the air source heat pump is running but the room temperature fails to reach the set value, it is usually caused by the following reasons:
1) Refrigerant problem: Insufficient refrigerant or a leak in the system.
2) Heat exchanger blockage: The evaporator or condenser fins accumulate a large amount of dust, leading to a decrease in heat exchange efficiency.
3) Airflow obstruction: The air filter is dirty and clogged, or the outdoor unit's air inlet is blocked by debris or vegetation.
4) Improper air source heat pump selection: The air source heat pump's power is too small to meet the overall heating needs of the house.
![]()
2. Air Source Heat Pump Fails to Start or Suddenly Stops
If the compressor fails to operate or the air source heat pump frequently starts and stops, possible causes include:
1) Power and Circuit Failure: Power outage, unstable voltage (such as during peak electricity usage), blown fuse, or circuit breaker tripping.
2) Protection Device Trigger: Triggering the compressor's time-delay protection function (usually requiring a wait of about 3 minutes), overheat protection, or a malfunction in the water flow switch in the water system.
3) Core Component Damage: Incorrect/damaged control panel settings, compressor malfunction, or stuck AC contactor.
3. Abnormal Noise and Vibration
If the air source heat pump emits a loud, "rock concert" sound, typically a humming, rubbing, or rattling noise:
1) Loose Components: Panels, pipe supports, or fixing screws may have loosened due to prolonged vibration.
2) Fan Failure: Deformed or unbalanced fan blades, or severely worn motor bearings.
3) Improper Installation: Uneven installation of the air source heat pump or incorrect duct layout amplifies the noise.
4. Severe Frosting or Poor Defrosting
Slight frost formation on the outdoor unit surface is normal during winter operation. However, if ice covers the air source heat pump and cannot melt naturally, it indicates a malfunction:
1) Defrosting Cycle Failure: A faulty defrost sensor or a stuck four-way valve prevents normal switching to defrost mode.
2) Environmental Factors: Poor ventilation around the air source heat pump, snow covering the air inlet, or excessively high ambient humidity.
5. Water Leakage
Water leakage requires attention and mainly falls into two categories:
1) Water Tank Leakage: Corrosion and perforation of the inner tank, aging of the sealing ring, or loose inlet/outlet water pipe connections.
2) Refrigerant Leakage: This not only affects operation but also involves environmental and safety concerns, usually accompanied by a hissing sound.
6. Control System and Display Errors
1) Thermostat Malfunction: A depleted battery, incorrect settings, or compatibility issues between the smart thermostat and the air source heat pump cause signal transmission interruption.
2) Display Codes: The panel displays specific fault codes such as E1/E2, which usually indicate a specific fault in an internal sensor or mainboard.
Safety Tips:
For simple routine maintenance of air source heat pumps (such as cleaning surrounding debris and cleaning the filter), users can handle it themselves. However, for complex issues involving refrigerant replenishment, circuit board repair, or compressor noise, please always contact professional after-sales service personnel. Do not disassemble delicate components yourself.
Air source heat pumps may encounter various malfunctions during daily use, which can be mainly summarized into the following categories:
1. Poor heating/cooling performance or low efficiency
This is one of the most common complaints. When the air source heat pump is running but the room temperature fails to reach the set value, it is usually caused by the following reasons:
1) Refrigerant problem: Insufficient refrigerant or a leak in the system.
2) Heat exchanger blockage: The evaporator or condenser fins accumulate a large amount of dust, leading to a decrease in heat exchange efficiency.
3) Airflow obstruction: The air filter is dirty and clogged, or the outdoor unit's air inlet is blocked by debris or vegetation.
4) Improper air source heat pump selection: The air source heat pump's power is too small to meet the overall heating needs of the house.
![]()
2. Air Source Heat Pump Fails to Start or Suddenly Stops
If the compressor fails to operate or the air source heat pump frequently starts and stops, possible causes include:
1) Power and Circuit Failure: Power outage, unstable voltage (such as during peak electricity usage), blown fuse, or circuit breaker tripping.
2) Protection Device Trigger: Triggering the compressor's time-delay protection function (usually requiring a wait of about 3 minutes), overheat protection, or a malfunction in the water flow switch in the water system.
3) Core Component Damage: Incorrect/damaged control panel settings, compressor malfunction, or stuck AC contactor.
3. Abnormal Noise and Vibration
If the air source heat pump emits a loud, "rock concert" sound, typically a humming, rubbing, or rattling noise:
1) Loose Components: Panels, pipe supports, or fixing screws may have loosened due to prolonged vibration.
2) Fan Failure: Deformed or unbalanced fan blades, or severely worn motor bearings.
3) Improper Installation: Uneven installation of the air source heat pump or incorrect duct layout amplifies the noise.
4. Severe Frosting or Poor Defrosting
Slight frost formation on the outdoor unit surface is normal during winter operation. However, if ice covers the air source heat pump and cannot melt naturally, it indicates a malfunction:
1) Defrosting Cycle Failure: A faulty defrost sensor or a stuck four-way valve prevents normal switching to defrost mode.
2) Environmental Factors: Poor ventilation around the air source heat pump, snow covering the air inlet, or excessively high ambient humidity.
5. Water Leakage
Water leakage requires attention and mainly falls into two categories:
1) Water Tank Leakage: Corrosion and perforation of the inner tank, aging of the sealing ring, or loose inlet/outlet water pipe connections.
2) Refrigerant Leakage: This not only affects operation but also involves environmental and safety concerns, usually accompanied by a hissing sound.
6. Control System and Display Errors
1) Thermostat Malfunction: A depleted battery, incorrect settings, or compatibility issues between the smart thermostat and the air source heat pump cause signal transmission interruption.
2) Display Codes: The panel displays specific fault codes such as E1/E2, which usually indicate a specific fault in an internal sensor or mainboard.
Safety Tips:
For simple routine maintenance of air source heat pumps (such as cleaning surrounding debris and cleaning the filter), users can handle it themselves. However, for complex issues involving refrigerant replenishment, circuit board repair, or compressor noise, please always contact professional after-sales service personnel. Do not disassemble delicate components yourself.