Building Long Range Control Residential Air Source Heat Pump R410A
Negotiable
MOQ
Negotiable
Price
Building Long Range Control Residential Air Source Heat Pump R410A
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: LN
Certification: CE ISO CCC ROHS
Model Number: KFXRS-100II
High Light:

R410A Residential Air Source Heat Pump

,

Cryogenic Operation waterproof Heat Pump

,

380V Residential Air Source Heat Pump

Payment & Shipping Terms
Packaging Details: standard export package, or as per customer request
Delivery Time: 1-30 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
Specifications
Compressor: Copeland
Performance COP (C.O.P.): 5.0
Max Pool Volume (m3 / Gal): 600 / 158400
Water Side Heat Exchanger: Shell & Tube
Operating Voltage: 220-380-410V
Heating Exchanger: Titanium, Which Can Withstand Prolonged Exposure To Swimming Pool Water
Product Description

Description of Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
 
Function
1.UnderFloor Radient Heating, air conditioner
2. Cooling
3. Hot water


Feature

This air circulation pump water heater includes a compressor, a heat exchanger and a heat storage tank. The compressor is provided with an air inlet and an air outlet. The air outlet is connected to the heat exchanger through an exhaust pipe. There is a circulating pump in the room. Compared with the prior art, the beneficial technical effect of the present invention lies in that the low-temperature water in the heat storage tank is sent to the heat exchanger by arranging a circulating pump between the heat storage tank and the heat storage tank. Due to the existence of the circulating pump, the low-temperature water can enter the heat exchanger faster to complete the heat exchange, so the water pressure during the hot water supply is guaranteed, and the use of high-level users is guaranteed.

Water leakage alarm automatically replenish water

Leomon air source heat pumps anti-leakage alarm automatic water filling device is a national patent product, which is applied to the water system of floor heating air conditioner. It can not only solve the automatic water filling of the water system but also judge the system water leakage to reach the alarm function. Users can use APP to supplement water in real time to avoid the trouble of manual hydration.

Application
1. Apartment
2. House
3. Villa
4. Factory
5. Hotel
6. School
7. Hospital
8. Commercial building

Radient underloor/centre air conditioner, heating, cooling, hot water
Advantage of 
Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
1. Adopted with world-famous brand(Copeland) compressor and other components.
2.
Durable, reliable, quiet, and efficient.
3. Intelligent remote wifi control offers comfortable heating or cooling.

4. Three temperature control

Real-time detection of water temperature

Leomon air source heat pumps air energy tank adopts three-point temperature control technology, which can monitor the water temperature in real time to ensure that the hot water is ready to use.

Modular control system to reduce energy loss

Provide moderate energy demand according to the end to reduce energy loss

Dual working conditions wide-frequency diversion technology to extend the life of the unit

Combining temperature compensation technology to ensure that the compressor reaches the best working condition under temperature changes, prolong the service life and improve work efficiency

Integration of main engine accessories Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump

The heat pump includes a housing, a heating system and an electrical system are arranged inside the housing, a fan is arranged above the housing, a radiator is arranged at the middle and upper part of the housing, and the radiator is connected to the Match the fan. The shell is installed on the base. The length of the base is 1500 mm. The utility model has the advantages of firm assembly of the unit, no distortion, deformation, cracks and scratches, a fan and a radiator for part of the necessary heat dissipation, and the water heater has the advantages of higher working efficiency, low cost, and simple structure.

Company introduction
Leomon supply
 most products in HVAC field, such as Rooftop Packaged Unit, Split Commercial Unit, Air Cooled Water Chiller, Water Cooled Water Chiller, Chilled Water Air Handling Unit and Fan Coil Unit etc.Decades production experience, its own labotory, over 380patents, norminated supplier for buildings, leader member for ediiting air source heat pumps standard, about 80000pcs air to water heat pumps production capacity a year!
 
Quality control:
100% inspection for each product, 3 phrases test before delivery, free spares supply, good prize if found any unqualified items
 
Production line:
3 production lines to guarantee production capacity and quick delivery, 2 shifts working
 
Technical paremeters of
Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump

Item KFXRS-23II
Nominal heating capacity at room temperature(kW) 23
Nominal input power
at room temperature(kW)
5.2
Rated voltage(Hz) 380V 3N ~ 50
Low temperature
nominal heatingWkW)
18.5
Low temperature
nominal input power(kW)
5
Maximum input power(kW) 6.8
Maximum current(A) 11
noisedb(A) <60
Anti-shock level I
waterproof level IPX4
Caliber of inlet and outlet DN32
Unit size (mm) 1010x410x1390
Unit Weight kg) 126

 

Item KFXRS-170II
Nominal heating capacity
at room temperature(kW)
170
Nominal input power
at room temperature(kW)
38
Rated voltage(Hz) 380V3N-50
Low temperature
nominal heatingWkW)
138
Low temperature
nominal input power(kW)
37.8
Maximum input power(kW) 65
Maximum current(A) 90
noisedb(A) <68
Anti-shock level I
waterproof level IPX4
Caliber of inlet and outlet DN80
Unit size (mm) 2360x1550x1840
Unit Weight kg) 1050

The nominal working conditions at room temperature are: ambient dry bulb 20°C, ambient wet bulb 15°C, initial water temperature 15°C, and ending water temperature 55.

(2; The nominal low temperature conditions are: ambient dry bulb 72, ambient wet bulb 61, initial water temperature 15°C, and ending water temperature 55℃.


Building Long Range Control Residential Air Source Heat Pump R410A 0

Recommended Products
Get in touch with us
Tel : 15215554137
Fax : 86-555-2842689
Characters Remaining(20/3000)