Description of Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
Function
1.UnderFloor Radient Heating, air conditioner
2. Cooling
3. Hot water
Feature
This air circulation pump water heater includes a compressor, a heat exchanger and a heat storage tank. The compressor is provided with an air inlet and an air outlet. The air outlet is connected to the heat exchanger through an exhaust pipe. There is a circulating pump in the room. Compared with the prior art, the beneficial technical effect of the present invention lies in that the low-temperature water in the heat storage tank is sent to the heat exchanger by arranging a circulating pump between the heat storage tank and the heat storage tank. Due to the existence of the circulating pump, the low-temperature water can enter the heat exchanger faster to complete the heat exchange, so the water pressure during the hot water supply is guaranteed, and the use of high-level users is guaranteed.
Water leakage alarm automatically replenish water
Leomon air source heat pumps anti-leakage alarm automatic water filling device is a national patent product, which is applied to the water system of floor heating air conditioner. It can not only solve the automatic water filling of the water system but also judge the system water leakage to reach the alarm function. Users can use APP to supplement water in real time to avoid the trouble of manual hydration.
Application
1. Apartment
2. House
3. Villa
4. Factory
5. Hotel
6. School
7. Hospital
8. Commercial building
Radient underloor/centre air conditioner, heating, cooling, hot water
Advantage of Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
1. Adopted with world-famous brand(Copeland) compressor and other components.
2. Durable, reliable, quiet, and efficient.
3. Intelligent remote wifi control offers comfortable heating or cooling.
4. Three temperature control
Real-time detection of water temperature
Leomon air source heat pumps air energy tank adopts three-point temperature control technology, which can monitor the water temperature in real time to ensure that the hot water is ready to use.
Modular control system to reduce energy loss
Provide moderate energy demand according to the end to reduce energy loss
Dual working conditions wide-frequency diversion technology to extend the life of the unit
Combining temperature compensation technology to ensure that the compressor reaches the best working condition under temperature changes, prolong the service life and improve work efficiency
Integration of main engine accessories Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
The heat pump includes a housing, a heating system and an electrical system are arranged inside the housing, a fan is arranged above the housing, a radiator is arranged at the middle and upper part of the housing, and the radiator is connected to the Match the fan. The shell is installed on the base. The length of the base is 1500 mm. The utility model has the advantages of firm assembly of the unit, no distortion, deformation, cracks and scratches, a fan and a radiator for part of the necessary heat dissipation, and the water heater has the advantages of higher working efficiency, low cost, and simple structure.
Company introduction
Leomon supply most products in HVAC field, such as Rooftop Packaged Unit, Split Commercial Unit, Air Cooled Water Chiller, Water Cooled Water Chiller, Chilled Water Air Handling Unit and Fan Coil Unit etc.Decades production experience, its own labotory, over 380patents, norminated supplier for buildings, leader member for ediiting air source heat pumps standard, about 80000pcs air to water heat pumps production capacity a year!
Quality control:
100% inspection for each product, 3 phrases test before delivery, free spares supply, good prize if found any unqualified items
Production line:
3 production lines to guarantee production capacity and quick delivery, 2 shifts working
Technical paremeters of Cryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
Item | KFXRS-23II |
Nominal heating capacity at room temperature(kW) | 23 |
Nominal input power at room temperature(kW) |
5.2 |
Rated voltage(Hz) | 380V 3N ~ 50 |
Low temperature nominal heatingWkW) |
18.5 |
Low temperature nominal input power(kW) |
5 |
Maximum input power(kW) | 6.8 |
Maximum current(A) | 11 |
noisedb(A) | <60 |
Anti-shock level | I |
waterproof level | IPX4 |
Caliber of inlet and outlet | DN32 |
Unit size (mm) | 1010x410x1390 |
Unit Weight kg) | 126 |
Item | KFXRS-170II |
Nominal heating capacity at room temperature(kW) |
170 |
Nominal input power at room temperature(kW) |
38 |
Rated voltage(Hz) | 380V3N-50 |
Low temperature nominal heatingWkW) |
138 |
Low temperature nominal input power(kW) |
37.8 |
Maximum input power(kW) | 65 |
Maximum current(A) | 90 |
noisedb(A) | <68 |
Anti-shock level | I |
waterproof level | IPX4 |
Caliber of inlet and outlet | DN80 |
Unit size (mm) | 2360x1550x1840 |
Unit Weight kg) | 1050 |
The nominal working conditions at room temperature are: ambient dry bulb 20°C, ambient wet bulb 15°C, initial water temperature 15°C, and ending water temperature 55.
(2; The nominal low temperature conditions are: ambient dry bulb 72, ambient wet bulb 61, initial water temperature 15°C, and ending water temperature 55℃.