Features of 20HP 72.8 KW Split Heat Pump For Household Hot Water Bathroom
This is a high-temperature split heat pump water heater, which includes an evaporator, a compressor and a titanium tube condenser. The output port of the evaporator is fixedly connected with a pipe, and is connected to the four-way valve through the pipe. The remaining valve ports on the four-way valve Then through the pipeline respectively with the compressor and the titanium tube condenser. This high-temperature split heat pump water heater is equipped with evaporator, compressor and titanium tube condenser, because the fan is separated from the evaporator, it is more convenient to use as an air conditioner; and the installation is more convenient, so that the volume and weight of the host are reduced and easier Installation, and the compressor can elevate the gas from low pressure to high pressure, and transport it to the titanium tube condenser for cooling, which is convenient for customers to use as an air conditioner to cool the factory
For further specification of Inverter 20HP 72.8 KW Split Heat Pump For Household Hot Water Bathroom Use and other specifications, welcome to contact us!
Unit type | SJKRS-73 I/C | |
Specifications | 20HP | |
Power supply | Three-phase five-wire380V/50Hz | |
Heating mode | Direct heat/cycle type | |
Standard working condition | Heating capacity( kw ) | 72.8 |
Input Power(kW) | 16.1 | |
COP | 4.5 | |
Hot Water flow(m³/h) | 1.56 | |
High temperature condition | Heating capacity kw ) | 59.5 |
Input Power(kW) | 18.6 | |
COP | 3.2 | |
Hot Water flow(m³/h) | 0.68 | |
Low temperature condition | Heating capacity( kw ) | 41.5 |
Input Power(kW) | 14.8 | |
COP | 2.8 | |
Hot Water flow(m³/h) | 0.78 | |
Component Information | Size of water pipe joint | DN25 |
Water heat exchanger | Plate or sleeve heat exchanger | |
Air Heat Exchanger | Aluminum Fin for copper tube | |
compressor type | Semi-closed reciprocating | |
Operation Panel | Color touch screen | |
Maximum outlet temperature(℃) | 90℃ | |
Refrigerants | R744 (CO2 ) | |
Design pressure(MPa) | High side 15, low side 8 | |
Dimensions (length, width and height mm) | 2050x1150x1950 | |
Noise (dB) | 67 | |
Weight(kg) | 860 | |
SCOPE of use | Feed water temperature(℃) | 5~ 40 |
Feed water pressure | 0.05~ 0.4 | |
Effluent temperature(℃) | 55~ 90 | |
Maximum flow | 3.2 | |
Ambient temperature(℃) | ’-20~43 |
2) high temperature effluent: Ambient Temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 90 ° c;
1) standard working conditions: ambient temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C, termination water temperature 55 ° c;
3) low temperature working condition: ambient temperature DB-10 °C, using side initial water temperature 9 °C, termination water temperature 55 °c;