Water Chillers Air Source 90KW Household Chiller Heat Pump IPX4
Negotiable
MOQ
Negotiable
Price
Water Chillers Air Source 90KW Household Chiller Heat Pump IPX4
Features Gallery Product Description Request A Quote
Features
Basic Infomation
Place of Origin: China
Brand Name: LN
Certification: CE ISO CCC
Model Number: KFXRS-19I
High Light:

DN32 Chiller Heat Pump

,

IPX4 Chiller Heat Pump

,

90KW Chiller Heat Pump

Payment & Shipping Terms
Packaging Details: standard export package, or as per customer request
Delivery Time: 1-30 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 80000pcs/year
Specifications
Power Supply: 220V-50HZ
Heating Capacity: 90 KW
Running Temp: -25℃~45℃
Max Water Temp: 40℃
Multi-functions: Heating And Cooling Hot Water
Running Temp: -10℃~45℃
Product Description

Small Household Air - Cooled Hot - Water Chillers Air Source Heat Pump

Applicable: villas, hotels, families, shopping malls, office buildings, exhibition halls, restaurants, factories and other places.

Product introduction: small household air cooled water chiller is a central air conditioning unit with air as cold (heat) source. As a combination of cold and heat sources, the air cooled heat pump eliminates the cooling tower and cooling water pump compared with the traditional central air conditioning. Boilers and corresponding piping systems and other auxiliary accessories can meet the needs of building refrigeration and heating throughout the year. The air-cooled heat pump system has the advantages of simple structure, saving installation space, convenient maintenance and management and high efficiency and energy saving. The centralized central air conditioning system, which is composed of air cooled heat pump unit, multi-fan coil unit and air conditioning box, has the advantages of flexible arrangement and diversified control.

 

Features:

A heat pump water heater control method, device and heat pump water heater are adopted. The heat pump water heater includes a water tank, and the heat pump water heater control method includes: water temperature; according to the ambient temperature, the water temperature, the water temperature, the amount of water in the water tank and Heat pump water heater performance parameters, calculate the heating time required to heat the water in the water tank to the water temperature; determine the heating start time of the heat pump water heater according to the water use time and the heating time, and the system time reaches the required time When the start time is stated, the heat pump water heater is started for heating. This avoids the problem of excessive energy wasted due to heat dissipation problems due to heat dissipation problems due to the heat pump water heater’s extended time to complete the heating in advance

 

Leomon heat pumps strength for Small Household Air - Cooled Hot - Water Chillers Air Source Heat Pump

Gold - aluminum condensation process rapid frost

Adopts American gold-aluminum finned evaporator technology and unique precious metal coating, which can effectively improve the evaporation efficiency of air and rain water according to the operation condition of air energy in special environment. -25℃ can also be highly effective for heating.

 

American SCL heat exchange technology high efficiency heating

American SCL technology has high heat transfer efficiency. Adopts precious metal coating to prevent scaling and withstand pressure up to 30KG. Specially used in air energy products, it is an alternative product for stainless steel plate and tube type heat exchanger.

 

Closed refrigerant system, safe and stable

Fluorine refrigerant system leakage points, easy to lead to frequent leakage of refrigerant, reduce equipment performance and service life. Bolang water machine system adhere to the international standard of closed refrigerant design, the unit in high or low temperature conditions also has excellent heat transfer efficiency.

Our strong and professional technical and marketing team ready to make best service!

Pre order(Inquiry progress):

Check with customer about usage, request specifications, enviroment and other request

Make details proposal/offer to customer

Order Processing

  • Machine installed and tested by QA engineers.

  • Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.

  • Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.

  • Test and debug the equipments strictly to ensure the safety and stability.

  • During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers

  • After sale service

  • 2 years warranty

  • Feedback and solution will be provided within 1 working day

  • Free technical support!

Small Household Air - Cooled Hot - Water Chillers Air Source Heat Pump

Item KFXRS-19I
Nominal heating capacity at room temperature(kW) 19
Nominal input power
at room temperature(kW)
4.19
Rated voltage(Hz) 220V-50
Low temperature
nominal heatingWkW)
15.5
Low temperature
nominal input power(kW)
4.18
Maximum input power(kW) 8
Maximum current(A) 32
noisedb(A) <66
Anti-shock level I
waterproof level IPX4
Caliber of inlet and outlet DN32
Unit size (mm) 1030x410x1390
Unit Weight kg) 126