R134A Air Source Heating System Heat Pump Air To Water For Office Buildings High COP Scroll Compressor
This enhanced heat pump boiling water unit solves the technical problems of low thermal efficiency, serious pollution, high cost, limited capacity, and serious scaling of existing high-temperature hot water equipment. The enhanced heat pump boiling unit of the utility model includes a body, a heat pump unit, and a PID or thermoelectric heater. The heat pump unit and the PID or thermoelectric heater are located in the body, and the water inlet of the heat pump unit is externally connected to a water source. The water outlet is connected to the PID, the water inlet of the thermoelectric heater. After the heat pump unit of the utility model is combined with the PID, that is, the thermoelectric heater, the thermal efficiency can be increased by about 50%, the equipment cost is low, the capacity can be large or small, and there is no pollution.
Applicable places: places such as factory dormitories, hotels, schools, hospitals, apartments, beauty salons, villas, swimming pool constant temperature, breeding constant temperature, high temperature hot water of electroplating factory, high temperature hot water of slaughterhouse, etc.
Advantages: Compared with traditional water heaters, it is energy-saving and environmentally friendly, safe and reliable, and is not limited by the installation site.
Features: Fully automatic control, small footprint
Strength of Leomon R134A Air Source Heating System Heat Pump Air To Water For Office Buildings High COP Scroll Compressor
A kind of refrigerating heat pump used, including low-temperature heat pumps and high-temperature heat pumps of the same structure; each heat pump includes an evaporator, a compressor and a condenser connected by pipelines, and the outlet of the condenser is connected to the evaporator through pipeline one The inlet of the heat pump is equipped with a throttling device on the first line of the pipeline. The refrigerant flows through the compressor, condenser, throttling device, and evaporator in sequence, and then flows back to the compressor, where it circulates; the condenser and high temperature of the low-temperature heat pump The evaporators of the group heat pumps exchange heat through heat exchange equipment. The structure of the utility model is reasonable in design. Through the utility model, the freezing low temperature of -25°C or even lower can be reached, and the boiler high temperature of 85°C can be reached, and the energy-saving effect is remarkable.
Some technical paremeters for R134A Air Source Heating System Heat Pump Air To Water For Office Buildings High COP Scroll Compressor
Spec. | KRY-24II |
Rated heating capacity(A24/26oC) | 24kw |
Rated power(kW) | 4.7 |
COP | 5.1 |
Rated heating capacityA20/26oC | 21kw |
Rated power(kW) | 4.5 |
COP | 4.66 |
Cooling Capacity(kW) | 11.3 |
Consumed Power(kW) | 4.9 |
EER | 2.3 |
Rated voltage(Hz) | 380V 3N-50HZ |
Maximum input power(kW) | 6 |
Maximum current(A) | 24 |
Water flownWh | 7 |
noise dB(A) | <65 |
Anti-shock level | I |
waterproof level | IPV4 |
Unit size (mm) | 780x820x1700 |
Unit Weight(kg) | 260 |