Basic Infomation
Place of Origin: China
Brand Name: LN
Certification: CE ISO CCC ROHS
Model Number: SJKRS-05I/C
High Light:

CO2 Cascade AC Inverter Heat Pump

,

45Kw AC Inverter Heat Pump

,

Integral Cascade Carbon Dioxide Heat Pump

Payment & Shipping Terms
Packaging Details: standard export package, or as per customer request
Delivery Time: 1-30 working days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
Specifications
Heating Type: Multi-power Heat
Performance COP (C.O.P.): 5.0
Max Pool Volume (m3 / Gal): 600 / 158400
Water Side Heat Exchanger: Shell & Tube
Operating Voltage: 220-380-410V
Application: Villa Family, Sauna And Swimming Pool, Hotels
Product Description

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump
1. Liquid crystal display; carbon dioxide heat pump variable frequency drive, R134a unit is fixed frequency;

2. Refrigerant: carbon dioxide (R744) + R134a;

3. Setting range: heating 65/40℃, cooling 7/12℃;

4. Working condition: -45-43℃;

5. The CO2 heat pump unit and the R134a unit work at the same time during heating in winter;

6. The carbon dioxide heat pump unit adopts Italian Duling compressor;

7. Function: low temperature heater.

CO2 Refrigerant: Advantages 

①Non-flammable, non-toxic.

② Natural product.

3Does not require any special procedures to recover refrigerant

4 No need to reacquire.

5 No damage to the Ozone Layer.

6.ODP=0 (Ozone Threat Potential Value 0)2

7.GWP=1(Greenhouse Effect Potential Value 1)

8.Not subject to any country's tax and regulatory regulations.

Advantages for CO2  R744 Heat Pump:

1The water temperature can be up to 100℃, high temperature storage can reduce the volume of the water tank.

2 The working limit is-43℃, but the water still can be discharged efficiently.

3 Maximum COP is 5.5.And for the All-in-one Multifunctional Machine, its Maximum COP is 7.

4 All-in-one Machine can produce hot and cold water at the same time to achieve maximize the efficiencial energy utilization.

5.Can meet different water consumption.

6 Single mechanism coaxial 520kW can be combined with multiple modules.

⑦ Safety, with 6times for overpressure safety protection, water and electricity separation.

⑧ Intelligent frequengy conversion control can save 50% of the energy when defrosting.

9.Split design, especially for high-rise places that cannot be hoisted and transported.

10. Smart wireless APP control, can realize unmanned management.

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

 

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump

1.DC variable frequency two-stage compressor.

2. The Split-Type Machine can be configured with a maximum water tank volume is 2000L.

3.Integrated built-in water tank volume as 40L,180L, 220L, 260L, 320L

④ Product Functions: Single Hot Water Unit Machine, Water Boiler,Domestic Hot Water+ Heating+ Solar Heating.

(5 Suitable for houses, illas,small hotels, small factories, hospital disinfection, etc.

 

CO2Cascade AC Inverter Heat Pump

① AC inverter compressor.

② CPP/PLC main control, colorful touch screen.

3 Ultra-low temperature operation-43℃C.

④ Split or whole body machine, can be customized as prefer.

⑤ Product Function: Ultra-low Temperature Heating in winter, Cooling in summer.

3.Applicable to places requiring heating such as northern high-speed railway stations,supermarkets, factories, stadiums, hot 45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump els, farms etc.

CO2 Cascade AC Inverter Heat Pump

45 kw CO2 Cascade AC Inverter Heat Pump Integral ultra-low temperature cascade carbon dioxide heat pump

Type   LNF-45XW LNF-85XW LNF-125XW
Function Heating Capacity kW 46 84 125
  Hot Water Capacity L/H 8 14.5 21.4
  Heating Power Input kW 12.4 26.3 40.3
  COP W/W 3.7 3.2 3.1
Power Supply V/Ph/Hz 380V~ 415V~-50/60Hz
Rated Output Water Temperature 60
Maximum Output Water Temperature 70
Working Ambient Temperature Range (-)43-43
Water Connection Pipe Size mm DN32 DN40 DN50
Refrigerant Type R744/CO2+R134a
Dimensions mm 1803x830x2100 2045x1108x2300 2470x1370x2415
Noise Level dB(A) 52 56 66
Net Weight KG 620 1185 1500
Inverter AC
Standard Temperature Condition:        
Outdoor Dry Bulb Temperature 7"C Wet Bulb Temperature 6°C, Return Water Temperature 50°C Water Supply Temperature 55℃;

Application Diagram Pressure-bearing water tank 

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw 0

System Diagram Smart Control System

8kW household carbon dioxide all-in-one machine CO2 air source heat pump multifunctional

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw 1

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw 2

 


System schematic diagram

CO2 Cascade AC Inverter Heat Pump Integral Low Temperature 45Kw 3

 


 

Recommended Products
Get in touch with us
Tel : 15215554137
Fax : 86-555-2842689