| MOQ: | 1 |
| Price: | Negotiable |
| Standard Packaging: | standard export package, or as per customer request |
| Delivery Period: | 1-30 working days |
| Payment Method: | L/C, D/A, D/P, T/T, Western Union |
Our high-temperature heat pump is an air source heat pump water heater primarily used in commercial and some industrial settings. It is specifically designed to produce hot water at temperatures up to 80°C.
High-temperature heat pumps are popular with users living in cold regions where winter temperatures can drop to -30°C. These users require daily hot water. Typically, these users include schools, hospitals, hotels, restaurants, gyms, and some industrial sites.
Features:
1. Safety First: Water and electricity are stored separately for enhanced safety.
2. Instant Hot Water: Provides hot water up to 80°C on demand.
3. Advanced Refrigerant Technology: Utilizes a patented blended refrigerant suitable for high-temperature, high-pressure systems.
4. User-Friendly Interface: Employs a smart microprocessor and touchscreen display for easy operation and troubleshooting.
5. Top-Tier Components: Uses compressors, valves, motors, and heat exchangers from world-renowned brands, ensuring high efficiency and energy savings of up to 75%.
6. Comprehensive Protection Functions: Equipped with protection against high pressure, low pressure, and overheating.
7. All-Weather Operation: Maintains stable performance regardless of external conditions.
8. Material Selection: Available in metal or stainless steel casing.
9. Automatic Defrosting: Ensures optimal operation under various conditions.
Advantages
1. Compressor
Our large heat pumps use Copeland scroll compressors (USA), while small heat pumps use compressors, specifically designed for heat pumps with high efficiency.
2. Electrical Control System
Project control functions allow easy control of the circulation pump, water compensation, water supply, auxiliary electric heating, and PID automatic defrosting. Users can set different parameters according to different project needs and automate the entire system.
3. Shell and Tube Heat Exchanger
The heat pump uses a high-efficiency shell and tube heat exchanger with a heat exchange area 3.7 times that of bare tubes. Its unique design and compact spiral structure ensure sufficient heat exchange of the refrigerant.
4. Electronic Expansion Valve
We use Sanhua brand expansion valves and, combined with our company's control system, have developed a special electronic expansion controller. This controller utilizes digital technology to adjust the refrigerant based on temperature factors to achieve optimal flow and a higher COP value.
Specifications
| type | FKH-12I/GW | FKH-20II/GW | FKH-40II/GW |
| Side air outlet | Top out wind | Top out wind | |
| Power specifications | 220V~50Hz | 380V 3N~50Hz | 380V 3N~50Hz |
| Heating capacity under A1 operating condition(20) |
12kW | 20kW | 40kW |
| Heating consumption power under A1 working condition |
4.8kW | 8.2kW | 16.2kW |
| Heating capacity under A2 working condition(7) |
11.5kW | 19kW | 38kW |
| Heating consumption power under A2 working condition |
5.3kW | 8.7kW | 17.5kW |
| Heating capacity under A3 working condition(-12) |
10.5kW |
17kW | 35kW |
| Heating consumption power under A3 working condition |
5.3kW |
8.5kW | 19kW |
| Heating capacity under A4working condition(-20) |
9kW |
15kW | 30kW |
| Heating consumption power under A4 working condition |
5.6kW |
9.3kW | 18.5kW |
| Maximum operating current | 40A | 35A | 70A |
| discharge | 2.1m³/h | 3.5m³/h | 6.9m³/h |
| noise | ≤56dB(A) | ≤58dB(A) | ≤60dB(A) |
| Water side pressure loss | ≤72kPa | ≤75kPa | ≤75kPa |
| Unit size(length x width x height mm) | 1030×410×1390 | 860×780×1780 | 1550×780×1780 |
| CONNECT SIZE | DN32(hexagon nipples ) | DN32(hexagon nipples) |
DN40(hexagon nipples) |
| Unit weight(kg) | 160 | 212 | 412 |
Get More Help
Leomon offers high-quality ODM and OEM services, providing customized solutions to your needs. Contact us today for more information.
| MOQ: | 1 |
| Price: | Negotiable |
| Standard Packaging: | standard export package, or as per customer request |
| Delivery Period: | 1-30 working days |
| Payment Method: | L/C, D/A, D/P, T/T, Western Union |
Our high-temperature heat pump is an air source heat pump water heater primarily used in commercial and some industrial settings. It is specifically designed to produce hot water at temperatures up to 80°C.
High-temperature heat pumps are popular with users living in cold regions where winter temperatures can drop to -30°C. These users require daily hot water. Typically, these users include schools, hospitals, hotels, restaurants, gyms, and some industrial sites.
Features:
1. Safety First: Water and electricity are stored separately for enhanced safety.
2. Instant Hot Water: Provides hot water up to 80°C on demand.
3. Advanced Refrigerant Technology: Utilizes a patented blended refrigerant suitable for high-temperature, high-pressure systems.
4. User-Friendly Interface: Employs a smart microprocessor and touchscreen display for easy operation and troubleshooting.
5. Top-Tier Components: Uses compressors, valves, motors, and heat exchangers from world-renowned brands, ensuring high efficiency and energy savings of up to 75%.
6. Comprehensive Protection Functions: Equipped with protection against high pressure, low pressure, and overheating.
7. All-Weather Operation: Maintains stable performance regardless of external conditions.
8. Material Selection: Available in metal or stainless steel casing.
9. Automatic Defrosting: Ensures optimal operation under various conditions.
Advantages
1. Compressor
Our large heat pumps use Copeland scroll compressors (USA), while small heat pumps use compressors, specifically designed for heat pumps with high efficiency.
2. Electrical Control System
Project control functions allow easy control of the circulation pump, water compensation, water supply, auxiliary electric heating, and PID automatic defrosting. Users can set different parameters according to different project needs and automate the entire system.
3. Shell and Tube Heat Exchanger
The heat pump uses a high-efficiency shell and tube heat exchanger with a heat exchange area 3.7 times that of bare tubes. Its unique design and compact spiral structure ensure sufficient heat exchange of the refrigerant.
4. Electronic Expansion Valve
We use Sanhua brand expansion valves and, combined with our company's control system, have developed a special electronic expansion controller. This controller utilizes digital technology to adjust the refrigerant based on temperature factors to achieve optimal flow and a higher COP value.
Specifications
| type | FKH-12I/GW | FKH-20II/GW | FKH-40II/GW |
| Side air outlet | Top out wind | Top out wind | |
| Power specifications | 220V~50Hz | 380V 3N~50Hz | 380V 3N~50Hz |
| Heating capacity under A1 operating condition(20) |
12kW | 20kW | 40kW |
| Heating consumption power under A1 working condition |
4.8kW | 8.2kW | 16.2kW |
| Heating capacity under A2 working condition(7) |
11.5kW | 19kW | 38kW |
| Heating consumption power under A2 working condition |
5.3kW | 8.7kW | 17.5kW |
| Heating capacity under A3 working condition(-12) |
10.5kW |
17kW | 35kW |
| Heating consumption power under A3 working condition |
5.3kW |
8.5kW | 19kW |
| Heating capacity under A4working condition(-20) |
9kW |
15kW | 30kW |
| Heating consumption power under A4 working condition |
5.6kW |
9.3kW | 18.5kW |
| Maximum operating current | 40A | 35A | 70A |
| discharge | 2.1m³/h | 3.5m³/h | 6.9m³/h |
| noise | ≤56dB(A) | ≤58dB(A) | ≤60dB(A) |
| Water side pressure loss | ≤72kPa | ≤75kPa | ≤75kPa |
| Unit size(length x width x height mm) | 1030×410×1390 | 860×780×1780 | 1550×780×1780 |
| CONNECT SIZE | DN32(hexagon nipples ) | DN32(hexagon nipples) |
DN40(hexagon nipples) |
| Unit weight(kg) | 160 | 212 | 412 |
Get More Help