logo
Send Message
Products
PRODUCTS DETAILS
Home > Products >
Best 90 Degree High Temperature Air Source Heat Pump for Cooling and Heating

Best 90 Degree High Temperature Air Source Heat Pump for Cooling and Heating

MOQ: 1
Price: Negotiable
Standard Packaging: standard export package, or as per customer request
Delivery Period: 1-30 working days
Payment Method: L/C, D/A, D/P, T/T, Western Union
Detail Information
Place of Origin
China
Brand Name
Leomon
Certification
CE ISO CCC ROHS
Model Number
LM90
High Cop:
4.18/4.19
Compressor:
DC Inverter Compressor
Noise:
50dB(A) Max
Function:
Heating And Cooling
Product Description

This high-temperature DC inverter heat pump water heater utilizes a dual-compressor, two-stage cascade operation to produce hot water. It perfectly combines the excellent low-temperature performance of R410A refrigerant with the high-temperature characteristics of R134a.

 

The first stage features a Mitsubishi R410A DC inverter compressor that adjusts its speed based on operating conditions and ambient temperatures, providing stable working conditions for the second stage. The second-stage R134a compressor then generates hot water at 90°C. The outlet water temperature can be set between 55°C and 90°C according to user requirements.

 

Applications: This high-temperature heat pump water heater meets heating needs across various sectors, including agricultural and by-product processing, beverage processing, electroplating and dyeing, textile printing and dyeing, drying, disinfection, and oil drilling.

 

Features

1. EVI Compressor Technology: Uses Copeland EVI compressors for efficient operation under diverse conditions.

2. Multi-Power Compatibility: Supports both 220V–240V single-phase and 380V–415V three-phase power supplies.

3. Comprehensive Safety Protection: Includes protections for temperature, timing, water flow, anti-freezing, and current, as well as pressure switch functions.

4. Flexible Customization: Offers options for full customization, small-batch customization, and production based on specific designs or samples.

5. Quality Certifications: Holds CE, ISO9001, CCC, CB, RoHS, SASO, and SGS certifications.

6. High Energy Efficiency: Achieves an energy efficiency ratio (COP) of 2.52–2.56, saving approximately 70% in energy compared to traditional heaters.

 

Advantages

1. Compressor

Our large-scale heat pumps utilize US-made Copeland scroll compressors, while small-scale models use compressors; both are specifically designed for heat pump applications and offer high operating efficiency.

 

2. Electrical Control System

The control system enables easy management of circulation pumps, water make-up, water supply, auxiliary electric heating, and PID automatic defrosting. Users can configure parameters to suit specific project requirements and achieve full system automation.

 

3. Shell-and-Tube Heat Exchanger

The heat pump utilizes a high-efficiency shell-and-tube heat exchanger with a heat transfer surface area 3.7 times that of bare-tube designs; its unique configuration and compact spiral structure ensure optimal heat exchange for the refrigerant.

 

4. Electronic Expansion Valve

We employ Sanhua expansion valves integrated with our proprietary control system to create a specialized electronic expansion control unit. This system uses digital technology to adjust refrigerant flow based on temperature, ensuring optimal flow rates and achieving a higher COP.

 

Specifications

type FKH-10I/CGW FKH-18II/CGW FKH-35II/CGW
Side air outlet Top out wind Top out wind
Power specifications 220V~50Hz 380V 3N~50Hz 380V 3N~50Hz
Heating capacity under A1
operating condition(20)
10kW 18kW 35kW
Heating consumption power under A1
working condition
4.8kW 8.2kW 16.8kW
Heating capacity under A2 working
condition(7)
9.5kW 17kW 34kW
Heating consumption power under A2
working condition
5kW 8.9kW 17.9kW
Heating capacity under A3 working
condition(-12)
9.5kW 17kW 32kW
Heating consumption power
under A3 working condition
6.2kW 10.6kW 20.6kW
Heating capacity under A4working
condition(-20)
8kW 16kW 30kW
Heating consumption power
under A4 working condition
5.6kW 11.1kW 20.1kW
Maximum operating current 40A 35A 70A
discharge 1.7m³/h 3.1m³/h 6m³/h
noise ≤56dB(A) ≤58dB(A) ≤60dB(A)
Water side pressure loss ≤72kPa ≤75kPa ≤75kPa
Unit size (length ×widthx height mm) 1030×410×1390 860×780×1780 1550×780×1780
CONNECT SIZE DN32(hexagon
nipples))
DN32(hexagon
nipples))
DN40(hexagon
nipples)
Unit weight(kg) 160 215 415

 

Need Further Assistance

Leomon offers high-quality ODM and OEM services, providing solutions customized to your specific requirements. Contact us today for more information.

Products
PRODUCTS DETAILS
Best 90 Degree High Temperature Air Source Heat Pump for Cooling and Heating
MOQ: 1
Price: Negotiable
Standard Packaging: standard export package, or as per customer request
Delivery Period: 1-30 working days
Payment Method: L/C, D/A, D/P, T/T, Western Union
Detail Information
Place of Origin
China
Brand Name
Leomon
Certification
CE ISO CCC ROHS
Model Number
LM90
High Cop:
4.18/4.19
Compressor:
DC Inverter Compressor
Noise:
50dB(A) Max
Function:
Heating And Cooling
Minimum Order Quantity:
1
Price:
Negotiable
Packaging Details:
standard export package, or as per customer request
Delivery Time:
1-30 working days
Payment Terms:
L/C, D/A, D/P, T/T, Western Union
Product Description

This high-temperature DC inverter heat pump water heater utilizes a dual-compressor, two-stage cascade operation to produce hot water. It perfectly combines the excellent low-temperature performance of R410A refrigerant with the high-temperature characteristics of R134a.

 

The first stage features a Mitsubishi R410A DC inverter compressor that adjusts its speed based on operating conditions and ambient temperatures, providing stable working conditions for the second stage. The second-stage R134a compressor then generates hot water at 90°C. The outlet water temperature can be set between 55°C and 90°C according to user requirements.

 

Applications: This high-temperature heat pump water heater meets heating needs across various sectors, including agricultural and by-product processing, beverage processing, electroplating and dyeing, textile printing and dyeing, drying, disinfection, and oil drilling.

 

Features

1. EVI Compressor Technology: Uses Copeland EVI compressors for efficient operation under diverse conditions.

2. Multi-Power Compatibility: Supports both 220V–240V single-phase and 380V–415V three-phase power supplies.

3. Comprehensive Safety Protection: Includes protections for temperature, timing, water flow, anti-freezing, and current, as well as pressure switch functions.

4. Flexible Customization: Offers options for full customization, small-batch customization, and production based on specific designs or samples.

5. Quality Certifications: Holds CE, ISO9001, CCC, CB, RoHS, SASO, and SGS certifications.

6. High Energy Efficiency: Achieves an energy efficiency ratio (COP) of 2.52–2.56, saving approximately 70% in energy compared to traditional heaters.

 

Advantages

1. Compressor

Our large-scale heat pumps utilize US-made Copeland scroll compressors, while small-scale models use compressors; both are specifically designed for heat pump applications and offer high operating efficiency.

 

2. Electrical Control System

The control system enables easy management of circulation pumps, water make-up, water supply, auxiliary electric heating, and PID automatic defrosting. Users can configure parameters to suit specific project requirements and achieve full system automation.

 

3. Shell-and-Tube Heat Exchanger

The heat pump utilizes a high-efficiency shell-and-tube heat exchanger with a heat transfer surface area 3.7 times that of bare-tube designs; its unique configuration and compact spiral structure ensure optimal heat exchange for the refrigerant.

 

4. Electronic Expansion Valve

We employ Sanhua expansion valves integrated with our proprietary control system to create a specialized electronic expansion control unit. This system uses digital technology to adjust refrigerant flow based on temperature, ensuring optimal flow rates and achieving a higher COP.

 

Specifications

type FKH-10I/CGW FKH-18II/CGW FKH-35II/CGW
Side air outlet Top out wind Top out wind
Power specifications 220V~50Hz 380V 3N~50Hz 380V 3N~50Hz
Heating capacity under A1
operating condition(20)
10kW 18kW 35kW
Heating consumption power under A1
working condition
4.8kW 8.2kW 16.8kW
Heating capacity under A2 working
condition(7)
9.5kW 17kW 34kW
Heating consumption power under A2
working condition
5kW 8.9kW 17.9kW
Heating capacity under A3 working
condition(-12)
9.5kW 17kW 32kW
Heating consumption power
under A3 working condition
6.2kW 10.6kW 20.6kW
Heating capacity under A4working
condition(-20)
8kW 16kW 30kW
Heating consumption power
under A4 working condition
5.6kW 11.1kW 20.1kW
Maximum operating current 40A 35A 70A
discharge 1.7m³/h 3.1m³/h 6m³/h
noise ≤56dB(A) ≤58dB(A) ≤60dB(A)
Water side pressure loss ≤72kPa ≤75kPa ≤75kPa
Unit size (length ×widthx height mm) 1030×410×1390 860×780×1780 1550×780×1780
CONNECT SIZE DN32(hexagon
nipples))
DN32(hexagon
nipples))
DN40(hexagon
nipples)
Unit weight(kg) 160 215 415

 

Need Further Assistance

Leomon offers high-quality ODM and OEM services, providing solutions customized to your specific requirements. Contact us today for more information.