R410A Air To Water Hot Water Air Source Heat Pump
Features of R410A Air To Water Hot Water Air Source Heat Pump
This is a heating device that absorbs the heat energy of the air in the environment to heat water, because the power consumption is only 1/4 to 1/3 of the direct electric heating method, and it is less affected by the regional environment. It can be used in all seasons. Stable operation, therefore, the air energy water heater has become a new energy-saving hot water heating device. According to whether the compressor is equipped with a jet enthalpy device, air-energy cold and hot water machines are divided into two categories: conventional type and ultra-low temperature type. Among them, conventional air-energy hot water machines can operate stably in the environment of -7℃~43℃ for a long time. , Ultra-low temperature air-energy hot water machine runs stably for a long time in the environment of -26℃~43℃
R410A Air To Water Hot Water Air Source Heat Pump Usage
It is suitable for hot water supply in homes, schools, hospitals, hotels, SPA clubs and other occasions.
Performance characteristics of R410A Air To Water Hot Water Air Source Heat Pump
1. Adopt special heat pump compressor with high thermal efficiency and long life. The ultra-low temperature model is equipped with the quasi-two Yasuo jet enthalpy increase system to realize stable operation at low temperature of -26℃.
2. The unique enhanced evaporator structure and high-efficiency piping system can effectively improve the energy efficiency ratio in winter and reduce the frosting rate. With the intelligent heat pump defrosting system, it can ensure the energy efficiency of the heat pump in humid and low temperature.
3. Modular design, which can realize the joint control and remote monitoring of 16 units. Each unit has an independent frame structure, heating system, power distribution system, control system and protection function. When one of the units fails, it will not affect The normal operation of other units.
4. The advanced intelligent control system has comprehensive protection functions such as high pressure protection, low pressure protection, water shortage protection, leakage protection, phase loss protection, overload protection, antifreeze protection, exhaust temperature overheating protection, etc., convenient and simple management
For further specification of Inverter R410A Air To Water Hot Water Air Source Heat Pump Use and other specifications, welcome to contact us!
Spec. | KRY-24II | KRY-48II | KRY-96II |
Rated heating capacity(A24/26oC) | 24kw | 48kw | 96kw |
Rated power(kW) | 4.7 | 9.3 | 18.5 |
COP | 5.1 | 5.16 | 5.41 |
Rated heating capacityA20/26oC | 21kw | 44 kw | 90kw |
Rated power(kW) | 4.5 | 8.6 | 17.5 |
COP | 4.66 | 5.11 | 5.14 |
Cooling Capacity(kW) | 11.3 | 23.7 | 40 |
Consumed Power(kW) | 4.9 | 9.1 | 18.2 |
EER | 2.3 | 2.6 | 2.2 |
Rated voltage(Hz) | 380V 3N-50HZ | 380V 3N-50HZ | 380V 3N-50HZ |
The compressor | ZW61KA-TFP-52E(one sets ) | ZW61KA-TFP-52E(two sets ) | ZW61KA-TFP-52E(four sets ) |
Fan Quantity | 1 | 2 | 4 |
Fan Quantity(W) | 370×1 | 370×2 | 370×4 |
Fan speed(rpm) | 850 | 850 | 850 |
Maximum input power(kW) | 6 | 12 | 24 |
Maximum current(A) | 24 | 42 | 80 |
Water flownWh | 7 | 13 | 32 |
noise dB(A) | <65 | <68 | <69 |
Anti-shock level | I | I | I |
waterproof level | IPV4 | IPV4 | IPV4 |
Unit size (mm) | 780x820x1700 | 1550x780x1700 | 1550x1550x1700 |
Unit Weight(kg) | 260 | 380 | 760 |
Rated heating conditions: outdoor dry/wet bulb temperature is 24°C/19°C, hot water inlet temperature is 26°C, outlet water temperature is 28°C; | |||
Rated heating conditions: outdoor dry/wet bulb temperature is 20°C/15°C, hot water inlet temperature is 26°C, outlet water is 28°C; | |||
Rated Cooling conditions: outdoor dry/wet bulb temperature is 35°C, COOL water inlet temperature is 30°C, outlet water is 28°C. |
Specification for Compressor
Model | Refrigerant | Heating (kw) |
Input power (KW) |
Current (A) |
Large running current (A) |
Weight (kg) |
ZW61KA-TFP-52E | R22 | 21.86 | 3.12 | 9.6 | 14.4 | 30 |